easons why the vacuum degree of the vacuum degasser is not high

The reason why the vacuum degree of the vacuum deaerator is not high or zero:

1. The water in the vacuum pump is not filled or not filled with water

2. The vacuum tank or vacuum pipeline is not well sealed

3. The suction pipe or the discharge pipe mouth does not invade the drilling fluid

The reasons why the vacuum degree of the vacuum deaerator is not high or zero, how to eliminate?

1. Fill the separator with water

2. Tighten bolts or check the sealing performance of the vacuum pipeline

3. Invade it into the drilling fluid

The vacuum degasser is a special degassing equipment for processing gas-immersed drilling fluids. The degassing efficiency is as high as 95%. It is suitable for supporting various petroleum drilling solids control system. It can restore the specific gravity of the mud, stabilize the viscosity of the mud, and reduce the performance. The cost of drilling plays an important role. At the same time, it can also be used as a high-power agitator.

Xi'an HL solids control specializes in the production of various types of vacuum deaerator, welcome to send inquiry to us: sales@hlsolidscontrol.com.

Prev: What are the factors that affect the working efficiency of the cyclone Next: What do you need to pay attention to during the use of the sand pump